Columns for Macromolecular Liquid Chromatography: Gel Filtration, Gel Permeation, Size Exclusion Chromatography

Our stationary phases designed for Interaction Free GPC/SEC come in stainless steel columns of standard dimensions that fit any HPLC or LC (GPC, SEC, GFC) instrument.

Click picture for close up view
 
Column Selection Guide
Facts and Tips

Magic Triangle for Aqueous GPC
 
Columns for polymers soluble in water + salts/buffers, MeOH, acetonitrile
Suprema         pH 2 - 12
Proteema        pH < 7  for proteins
Novema          TFA, pH 1.5 -13
MCX                pH 1 - 14



Magic Triangle for Organic GPC
 
Columns for polymers soluble in Organic Solvents
SDV        THF, Toluene, Chloroform and Methylene chloride
GRAM      for DMF, DMAC, NMP, DMSO    Purchase
POLEFIN   for TCB, ODCB, Decalin
PFG      Hexafluoroisopropanol (HFIP), Trifluoro ethanol, (TFE)




Lux Columns
 
Columns for Light Scattering Detection
SDVLux
SupremaLux
POLEFINLux 
Lux columns reach the steady state mode > 25 times faster than conventional columns, and their overall noise reduction is more than 25 times better.

Traditional GPC/SEC columns can produce excessive baseline noise from particulates in the eluent stream, which can significantly deteriorate the quality of the light scattering detectors data (especially LALLS/LALS)  Normally a new column set needs a 'conditioning' process, which involves flushing the columns to waste without any detector connected.


One linear or Multiple columns
 
Mixed Bed Column vs. Column Combination
Comparison linear column XL with a column combination for high molar masses
One Linear Column: fast analysis time, broad molar mass range
Column combination: high resolution





analytical vs Highspeed
HighSpeed Calibration

 
HighSpeed vs. Analytical Columns

A HighSpeed column (red line) reduces the run time for a sample (broad Poly(styrene)) by a factor of 6 - 8 compared to a conventional column (black line).

HS will substitute for analytical columns without modifications to your LC system, as long as pump and detectors accommodate 6.25 ml/min. At this flow rate, you will speed up the measurement using the same amount of solvent you currently use.

Calibration with Poly(styrene) ReadyCal green, red, and white: each contains 4 different molecular weight standards


PSS offers a wide variety of column dimensions and will manufacture custom sizes upon request.
 
Type                      I.D x Length (mm)  
Guard columns        8 x 50; 4,6 x 30; 20 x 50        
Analytical                8 x 300 and 8 x 600  
Microbore                4,6 x 250  
Preparative              20 x 600  
HighSpeed               20 x 50

Analytical, HighSpeed and guard Columns may be purchased online.   Email us for a custom quote for analytical columns (8x600), Microbore and Preparative columns


back
next